You turn the thermostat down, wait, and nothing happens: no click, no fan, no hum from outside. An AC not turning on usually means power or the control signal isn't reaching the equipment. That's often simpler than a cooling failure. We connect you with a local AC tech in Neely, MS who can trace where the signal stops.
Quick checks before calling
- Thermostat on Cool, set at least 3 degrees below room temperature
- Fresh batteries in the thermostat, if it uses them
- The breaker for the indoor unit and the separate 240-volt breaker for the outdoor condenser
- The disconnect box on the wall by the outdoor unit, pulled out or switched off
- The furnace or air handler service switch (looks like a light switch, often near the unit)
- Water in the drain pan or a tripped float switch
Many thermostats also have a built-in delay of up to five minutes after a setting change, to protect the compressor. Give it a few minutes. If a breaker trips again right after reset, leave it off and call.
Indoor nothing versus outdoor nothing
If neither the indoor blower nor the outdoor unit starts, the problem is upstream: the thermostat, its wiring, the 24-volt transformer, a blown low-voltage fuse on the control board, or a float switch that's cut the circuit. Our thermostat repair page covers that side. If the indoor blower runs but the outdoor unit doesn't, the problem is at the condenser: a failed contactor, a dead capacitor, a tripped breaker, a broken low-voltage wire between the units, or a pressure switch that's locked the unit out.
What the tech checks
The tech starts with voltage. Is there 240 volts at the disconnect? 24 volts between R and C at the indoor board? Does the contactor get its 24-volt signal when the thermostat calls? Following that path finds the break. A buzzing contactor that won't pull in, a burned wire at a terminal, a chewed thermostat cable along the outside wall: these are the common finds. If the unit hums but won't start, the capacitor is the usual suspect, and our capacitor replacement page explains why.
Water and float switches
A clogged condensate drain is a sneaky cause of a dead AC. The float switch shuts the whole thing off to prevent overflow. If you see water in the pan, the fix is clearing the drain, covered on our AC leaking water page.
What drives the cost
A reset, a fuse or a wire repair is quick. A contactor, capacitor, transformer or control board costs more. After-hours visits usually carry a higher fee. Call (337) 568-0294 and we will connect you with a local AC company in Neely, MS.